Read Historical Data Using the System Variable tidb_snapshot
This document describes how to read data from the history versions using the system variable tidb_snapshot
, including specific usage examples and strategies for saving historical data.
Feature description
TiDB implements a feature to read history data using the standard SQL interface directly without special clients or drivers.
How TiDB reads data from history versions
The tidb_snapshot
system variable is introduced to support reading history data. About the tidb_snapshot
variable:
- The variable is valid in the
SESSION
scope. - Its value can be modified using the
SET
statement. - The data type for the variable is text.
- The variable accepts TSO (Timestamp Oracle) and datetime. TSO is a globally unique time service, which is obtained from PD. The acceptable datetime format is "2016-10-08 16:45:26.999". Generally, the datetime can be set using second precision, for example "2016-10-08 16:45:26".
- When the variable is set, TiDB creates a Snapshot using its value as the timestamp, just for the data structure and there is no any overhead. After that, all the
SELECT
operations will read data from this Snapshot.
After reading data from history versions, you can read data from the latest version by ending the current Session or using the SET
statement to set the value of the tidb_snapshot
variable to "" (empty string).
How TiDB manages the data versions
TiDB implements Multi-Version Concurrency Control (MVCC) to manage data versions. The history versions of data are kept because each update/removal creates a new version of the data object instead of updating/removing the data object in-place. But not all the versions are kept. If the versions are older than a specific time, they will be removed completely to reduce the storage occupancy and the performance overhead caused by too many history versions.
In TiDB, Garbage Collection (GC) runs periodically to remove the obsolete data versions. For GC details, see TiDB Garbage Collection (GC)
Pay special attention to the following:
tidb_gc_life_time
: This system variable is used to configure the retention time of earlier modifications (default:10m0s
).- The output of
SELECT * FROM mysql.tidb WHERE variable_name = 'tikv_gc_safe_point'
. This is the currentsafePoint
where you can read historical data up to. It is updated every time the garbage collection process is run.
Example
At the initial stage, create a table and insert several rows of data:
mysql> create table t (c int); Query OK, 0 rows affected (0.01 sec) mysql> insert into t values (1), (2), (3); Query OK, 3 rows affected (0.00 sec)View the data in the table:
mysql> select * from t; +------+ | c | +------+ | 1 | | 2 | | 3 | +------+ 3 rows in set (0.00 sec)View the timestamp of the table:
mysql> select now(); +---------------------+ | now() | +---------------------+ | 2016-10-08 16:45:26 | +---------------------+ 1 row in set (0.00 sec)Update the data in one row:
mysql> update t set c=22 where c=2; Query OK, 1 row affected (0.00 sec)Make sure the data is updated:
mysql> select * from t; +------+ | c | +------+ | 1 | | 22 | | 3 | +------+ 3 rows in set (0.00 sec)Set the
tidb_snapshot
variable whose scope is Session. The variable is set so that the latest version before the value can be read.mysql> set @@tidb_snapshot="2016-10-08 16:45:26"; Query OK, 0 rows affected (0.00 sec)Result: The read from the following statement is the data before the update operation, which is the history data.
mysql> select * from t; +------+ | c | +------+ | 1 | | 2 | | 3 | +------+ 3 rows in set (0.00 sec)Set the
tidb_snapshot
variable to be "" (empty string) and you can read the data from the latest version:mysql> set @@tidb_snapshot=""; Query OK, 0 rows affected (0.00 sec)mysql> select * from t; +------+ | c | +------+ | 1 | | 22 | | 3 | +------+ 3 rows in set (0.00 sec)
How to restore historical data
Before you restore data from an older version, make sure that Garbage Collection (GC) does not clear the history data while you are working on it. This can be done by setting the tidb_gc_life_time
variable as the following example shows. Do not forget to set the variable back to the previous value after the restore.
SET GLOBAL tidb_gc_life_time="60m";
To restore data from an older version, you can use one of the following methods: